PMS100 shows that PMS050 has been reported, but not PMS130 put-away for production.

If item is quality inspected and set up is done in LIS100, a record should have been created in LIS200. In this example there is no record, since it has been deleted. Other root cause, could be that it was reported in stock before set up was done in LIS100.

PMS130 – put-away for production can be opened directly.

 


Enter item- and lot number,

Confirm <NEXT>

Status can be updated as needed.

 


Confirm <NEXT>

PMS100 now shows manufactured quantity as to be expected.

Goods now have status 2.

From MMS235 + option 32 Reinspect Lab Inspection Report => this will generate a record in LIS200 (if set up in LIS100 is correct).

Record in LIS200 was created for LI spec type 2 – retest of approved lot.

And analyses results van be entered.